VERY LONG BASELINE ARRAY OBSERVING LOG -------------------------------------- Project: BC120DW Observer: Chatterjee, S. Project type: VLBA Obs filename: bc120dwcrd.* Date/Day: 2004APR06/097 Ants Scheduled: SC HN NL FD LA PT KP OV BR MK =UT-Time===Comment===============================================MF#===%AD==AMD= Operator is Cyrus M. Reed. VCLOCK and GPS DELTA OK. UT1-UTC OK (-0.44). WEA: Cloud cover via webcam unavailable; WEA: night at all sites. WEA: No recent precipitation at any site. 0812 Begin observing. Antennas on source. 0812-1012 *PT not observing due to scheduled maintenance. SCH 0812-0814 *BR EL brake fault - dis/enabled axis to clear. ACU 100 2 0819-0820 *BR EL brake fault - dis/enabled axis to clear. ACU 100 1 0824-0827 *SC antenna autostowed due to power failure. COM 100 3 Repointed - running on 150KW generator. 0843-0850 *SC AZ1 motor current jumped to 90A on restoration ACU 100 7 of commercial power. After some ACU resets and some other fiddling, was able to get motor current back under control and repoint. No readback checks this project. 1012 End. Downtime Summary: Total downtime : 13 min Percentage downtime of observing: 1.1% Average downtime per hour : 0.6 min Total scheduled observing time (# Antennas): 1200 min (10) Notes: * = Entries where data was affected. % = Entries where data may have been affected. & = Entries where the site tech was called out. WEA = Weather entries. MF# = Maintenance form or major downtime category associated with a problem. %AD = The percentage of an antenna affected by a problem. AMD = Total antenna-minutes downtime for a problem. Tsys = System Temperature (TP/SP x Tcal/2) ACU = Antenna Control Unit FRM = Focus/Rotation Mount RFI = Radio Frequency Interference VME = Site control computer CB = Circuit Breaker vclock = Program that compares site clock time to a standard.